Microphone sensitivity and conversion ratings audio engineering conversions acoustics calculation explained mic microphone transfer factor mV/Pa to sensitivity dB re 1 V/Pa or dyne/cm2 mV/Pa 0 dB mic sensibility equation formula microphone mic resistance impedance output voltage calculator - Eberhard Sengpiel sengpielaudio
 
Deutsche Version UK-flag s/w - sengpielaudio D-flag - sengpielaudio
 
Microphone sensitivity and conversion

1 – Sensitivity (new): dB re 1 V/Pa ← → Transfer factor: mV/Pa

International standards have established 1 pascal (Pa) as 94 dBSPL (sound pressure level).
This reference point is now accepted for specifying the sensitivity of microphones.
The μbar found in some non-European specifications refers to 74 dBSPL (20 dB less than 1 Pa) and the sensitivity or the sensitivity factor is not expressed as transfer factor in the usual form of "mV/Pa" as open circuit voltage rating. In the data sheets the sensitivity always applies to the frequency 1 kHz, unless otherwise noted.
Microphones simply convert the sound pressure deviations
p (pascal Pa) to audio voltage V (volts V).
Forget necessarily the energy as output power of the microphone!

Reference: 94 dBSPL ≡ 1 pascal = 10 µbars = 10 dynes/cm2
Auditory threshold: 0 dBSPL ≡ 0.00002 Pa = 0.0002 dyne/cm2
 
Fill out the respective box and click on the calculation button below. The sensitivity must be a negative dB value.
 
Sensitivity  dB re 1 V/Pa   |   Transfer factor  mV/Pa
   |  
 |
   |  
 Transfer factor  mV/Pa  | Sensitivity  dB re 1 V/Pa 
   |  
 
1 pascal = 10 µbars = 10 dynes/cm2 and 1 µbar = 1 dyne/cm2 = 0.1 pascal
1 mV/Pa = 0.1 mV/µbar or 1 mV/µbar = 10 mV/Pa and pascal = newton/m2

 
Calculation formulas: Sensitivity = 20 × log (transfer factor) and transfer factor = 10sensitivity/20
Given is the sensitivity in dB re 1 V/Pa and the transfer factor in V/Pa. 1 mV = 0.001 volts.

 
Transfer factor, at 1 kHz and 1 Pa ≡ 94 dB SPL
M = 50 mV/Pa or
Sensitivity (level), dB re 1V/Pa (1 kHz)
LM = 20 × log10 (M/MR) = −26 dBV
with MR = 1V/Pa

Microphone sensitivity conversion - sengpielaudio

2 – Sensitivity (old): dB re 1 V/dyne/cm2 ← → Transfer factor: mV/Pa

Microphone firms in the USA are partly still using the old sensitivity of "dB re 1 V/dyne/cm2"
or "dB re 1 V/µbar" (74 dBSPL) and do not show the usual form "mV/Pa".
In the data sheets the sensitivity always applies to the frequency 1 kHz, unless otherwise noted.
 
Reference: 74 dB-SPL ≡ 1 dyne/cm2 = 0.1 pascal = 1 µbar
Threshold of hearing: 0 dBSPL ≡ 0.0002 dyn/cm2 = 0.00002 Pa
 
Fill out the respective box and click the 'calculate' bar below. The sensitivity must be a negative dB value.
 
Sensitivity  dB re 1 V/dyne/cm²   |   Transfer factor  mV/Pa
   |  
 |
   |  
 Transfer factor  mV/Pa  | Sensitivity  dB re 1 V/dyne/cm² 
   |  
 
1 µbar = 1 dyne/cm2 = 0.1 Pascal and 1 pascal = 10 µbars = 10 dynes/cm2
1 mV/µbar or 1 mV/Pa = 0.1 mV/µbar = 10 mV/Pa and pascal = newton/m2
 
Pascal is written in English with lower-case letter beginning: We have the pascal and we have the dyne, and the plural dynes which are microbars. A typical condenser microphone, having 10 mV/Pa is the same as 1.0 mV/µbar; but 10 Pa are 100 µbar.
−40 dB "re 1V/Pa" equals to −60 dB "re 1V/microbar". There is a difference of 20 dB.
 
The sound pressure
p is precisely the sound pressure as an effective value (RMS).
 
 
 All field quantities, like voltage, or sound pressure are always 
 RMS values in audio engineering, unless otherwise stated.

 
 
An often heard question: Why are microphone output levels expressed in negative decibels (dB)?
Answer: Because all microphones produce a voltage level which is less than 1 volt ≡ 0 dB for the reference sound pressure level of 94 dB or 74 dB.
 
 
The sensitivity (transfer factor) in mV / Pa shows clearly that microphones change sound pressure (Pa) to audio voltage (mV).
Energy and power play no role for these microphone transducers.
Our eardrums are also moved by the sound pressure deviations.
Sound pressure as a sound field quantity cannot be the same like acoustic intensity or sound power as a sound energy quantity.

 

Note about power ratings
 
At the output of microphones there is no output power to find.
 
Forget the power ratings. They have no relevance to microphones. The term "dB SPL" is a measurement of Sound Pressure Level, or SPL which is the force per area that acoustical sound waves apply to air particles. Microphones are sensors in the sound field which deliver an analogous voltage. Microphones measure sound pressure, or sometimes they may measure the particle velocity, but they never measure sound intensity directly. Intensity stereo is an unfortunate linguistic misnomer which has come to mean the recording of stereophonic signals that are distinguished only by level differences. In stereo the level differences have been called "intensity" differences, but sound intensity is a specifically defined quantity and cannot be sensed by a simple microphone, nor would it be valuable in music recording if it could. "Intensity" stereophony is a misnomer and is better called level difference stereophony. Ears (earsdrum) are directly sensitive to sound pressure, like microphones (diaphragm). Forget both intensity and the power.
A studio microphone is never attached to a load equal to its own internal resistance. The load resistor (impedance) should always to be at least ten times greater than the internal source resistor of the microphone (open circuit). Here only voltage is important and not the power.
Sound intensity and energy are both energy and power quantities as well as computational tools for acousticians and sound protectors (noise fighters), and not so important for sound engineers.

 
Note: The output voltage of a microphone is proportional to the incident sound pressure.
 
To obtain the microphone maximum output level in dBu, find your microphone's sensitivity rating on
the left side and then move right until you are directly below your microphone's maximum SPL rating.
As an example, for a microphone with a sensitivity rating of 20 mV/Pa and a max SPL equal to 130 dB.
 
Table 1 tells us that the maximum output voltage is +4 dBu. You now have what you need to compare preamps regarding maximum input level.
 
Maximum Output Level

Microphone Dynamic Range Calculation

Enter any TWO of the following values, then press the calculate button.
The missing value will be calculated. 10 μbar = 1 pascal ≡ 94 dBSPL
rating is used here.
 
Max. SPL, e.g. 138  dB SPL
Self noise, e.g. 16  dB
Dynamic range  dB
 
            
 
 S/N ratio re 94 dB SPL  dB
 
Self-noise may be entered using any weighting factor (A, CCIR 468 etc.) but the dynamic range will be predicated by that weighting.
"S/N re 94 dB SPL" is 94 dB minus self noise.
The max. SPL for less than 0.5 % THD should be used. If you find there values for 1 % THD, then do a 6 dB subtraction, for a more correct comparison.
 
 
Note: There is no conversion formula for weighted dBA
           values to sound pressure level dBSPL or vice versa.

 
 
 
Pro audio equipment often lists an A-weighted noise spec
− not because it correlates well with our hearing − but because it can "hide" nasty hum components that make for bad noise specs.
 
Words to bright minds: Always wonder what a manufacturer is hiding when they use A-weighting.
 *)
 

*) http://www.google.com/search?q=Always+wonder+what+a+manufacturer+Rane

Readings of a pure 1 kHz tone should be identical, whether weighted or not.

Transfer factor in mV/Pa and sensitivity

To use the calculator, simply enter a value.
The calculator works in both directions of the
sign.
Transfer factor Europe + Intern.
mV/Pa (1 mV = 0.001 V)
 ↔  Sensitivity Europe + Intern.
dB re 1V/Pa
Transfer factor = 10Sensitivity / 20
Sensitivity in dB re 1 volt per pascal
  Sensitivity = 20×log(Transfer factor)
Transfer factor in volt per pascal
Reference level 94 dB-SPL ≡ 1 Pascal      1 000 mV/Pa ≡ 0 dB

The sensitivity must be a negative dB value.

Transfer factor USA (old)
mV/Pa
 ↔  Sensitivity USA (old)
dB re 1 dyn/cm²
 
 
  This number shows a 20 dB
"difference" to Europe.
Reference level 74 dB-SPL ≡ 1 dyn/cm²  10 000 mV/Pa ≡ 0 dB

The sometimes found microphone "power level" in dB is wrong.
It really has to be "sensitivity in dB re 1 V/Pa".

Interconnection of microphone and preamplifierZout < Zin
 
Data of condenser microphones in comparison

 
The sensitivity (transfer factor) in mV / Pa shows clearly that microphones are sensors and change sound pressure (Pa) to audio voltage (mV).
Energy and power plays no role for this microphone transducers. Our eardrums are effectively moved by the sound pressure deviations.

Sound pressure as sound field quantity cannot be the same as
sound intensity as sound energy quantity.
 
 
"Input sensitivity" is basically the same thing as sensitivity - putting the word "input" in front of it is somewhat redundant. Input sensitivity controls are commonly found on amplifiers and other audio equipment, but not on microphones.

Conversion of sound units (levels)
 
Acoustic equivalent for ohm's law

  1 Pa =   1 N/m2
  10 µbar
  10 dynes/cm2
          
1 µbar =   0.1 N/m2
  0.1 Pa
  1 dynes/cm2
 
In the "Specification Data" you will not find the word "electret microphone" because this fact is hidden by the term "pre-polarized condenser microphone".
 
 
 
back weiter Search Engine weiter home Start